Page 1 - MWI-13466

7550 Hub Parkway Cleveland, Ohio 44125 Phone: 216.524.8800 Fax: 216.642.2131 www.CMCcontrols.comINSTRUCTION MANU

Page 2 - REVISION HISTORY

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 10 OF 26 2.4 RECOGNITION DIAGRAMS Figure 2– Front and Side Views of Classic Series DIN Ra

Page 3 - TABLE OF CONTENTS

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 11 OF 26 Figure 4 - Internal Jumper-switches and Potentiometer Location 2.5 CONFIGURING

Page 4 - FURTHER INFORMATION

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 12 OF 26 2.6 POTENTIOMETERS In addition to the Gain and Zero adjustable Potentiometers vi

Page 5 - 1 PRODUCT OVERVIEW

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 13 OF 26 2.9 METER VOLTAGE/CURRENT CONFIGURATION The damped output for a tension indicato

Page 6 - ≤ 8 kohm

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 14 OF 26 • Do not pre-tin the stranded wires inserted into the pluggable connector. • A

Page 7 - 1.7 EMISSION SPECIFICATIONS

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 15 OF 26 2.12.2 OUTPUT WIRING The load in this connection may be an indicator, recorder,

Page 8 - PAGE 8 OF 26

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 16 OF 26 2.12.2.2 DAMPED +/- 1 MA ANALOG The meter output stage can be configured to ope

Page 9 - 2 SETUP AND CONFIGURATION

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 17 OF 26 3.1.2 POWER APPLICATION Apply DC power to the amplifier and use a DC voltmeter t

Page 10 - 2.4 RECOGNITION DIAGRAMS

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 18 OF 26 3.4 CHECKING TRANSDUCER MOUNTING Before preparing to apply force to the transduc

Page 11 - AGE 11 OF 26

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 19 OF 26 3.5 ACCURACY CONSIDERATIONS The application of an accurate calibration force req

Page 12 - XCITATION VOLTAGE SELECT

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 2 OF 26 REVISION HISTORY Rev ECO Author Date Description of Change AA XXX DJM A

Page 13 - 2.11.2 TRANSDUCER WIRING

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 20 OF 26 3.6 PROPER PRACTICES FOR APPLYING CALIBRATION FORCES Seldom is a transducer ori

Page 14 - 2.12.1 POWER WIRING DIAGRAM

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 21 OF 26 3.7 ADJUSTMENT TOOLS Using the correct tools simplifies making the necessary a

Page 15 - 2.12.2 OUTPUT WIRING

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 22 OF 26 3.8 ADJUSTING AMPLIFIER COARSE ZERO A coarse offset adjustment has been provided

Page 16 - 3 POWER-UP AND TESTING

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 23 OF 26 3.10 EMC CONNECTIONS AND INSTALLATION Compliance with the specified EMC directiv

Page 17 - 3.3.1 SAFETY CONSIDERATIONS

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 24 OF 26 Appendix A. MANUFACTURERS DECLARATION OF CONFORMITY Number: AO-90311 Manufa

Page 18 - HECKING TRANSDUCER MOUNTING

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 25 OF 26 Appendix B. CABLE GLANDS Several manufacturers provide cable glands that can b

Page 19 - CCURACY CONSIDERATIONS

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 26 OF 26 BLANK

Page 20 - AGE 20 OF 26

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 3 OF 26 TABLE OF CONTENTS 1 PRODUCT OVERVIEW...

Page 21 - 3.7 ADJUSTMENT TOOLS

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 4 OF 26 WARRANTY Cleveland Motion Controls warrants the goods against defects in design,

Page 22 - PAGE 22 OF 26

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 5 OF 26 1 PRODUCT OVERVIEW 1.1 GENERAL DESCRIPTION The Classic Series DIN Rail amplifier

Page 23 - AGE 23 OF 26

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 6 OF 26 1.2 GENERAL SPECIFICATIONS Item Specification Comments Input Supply Power Suppl

Page 24 - Number: AO-90311

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 7 OF 26 1.4 ENVIRONMENTAL REQUIREMENTS Requirement Description Enclosure IP20 NEMA 1 Ope

Page 25 - Appendix B. CABLE GLANDS

CLASSIC SERIES NON-ISOLATED AMPLIFIER MAN-13466 REV CA PAGE 8 OF 26 Figure 1 Block Diagram of Classic Series DIN RAIL MWI-13466

Page 26 - PAGE 26 OF 26

MAN-13466 REV CA CLASSIC SERIES NON-ISOLATED AMPLIFIER PAGE 9 OF 26 2 SETUP AND CONFIGURATION 2.1 LOAD CELL (TRANSDUCER) TERMINALS Input Terminal