INSTRUCTION MANUAL (MAN-13261) FOR DIN RAIL AMPLIFIER MWI-13261 ULTRA SERIESISOLATED 7550 Hub Parkway
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 2 SETUP AND CONFIGURATION 2.1 LOAD CELL (TRANSDUCER) TERMINALS Supply Terminal
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 2.4 RECOGNITION DIAGRAMS 1.999DIAGRAMWIRINGLEFT SIDE VIEWFRONT VIEWwww.CMCcontrols.comCMC PART
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA J1 Figure 4 - Internal Jumper-switches and Potentiometer Location 2.5 CONFIGURING
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 2.6 POTENTIOMETERS In addition to the Gain and Zero adjustable potentiometers visible on the f
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 2.9 GAIN SELECT SWITCHES The group of jumper-switches that control the fixed gain
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 2.12 WIRING Most start-up problems are the result of mis-wiring or failure to reference the de
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 2.13 THE POWER SUPPLY For best performance a regulated power supply should be used
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 2.13.2.1 4 TO 20 MA ANALOG CURRENT LOOP The 4-20 mA current loop output is undamped and can be
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 2.13.2.2 APPLICATION INTERFACE DETAILS The 4-20 mA output stage is designed to dri
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA While possible to interface the 4-20 mA current loop into circuits which do exhibit resistance
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA PAGE 2 OF 2 REVISION HISTORY Rev ECO Author Date Description of Change AA
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 2.13.2.4 DAMPED +/- 1 MA ANALOG The meter output stage can be configured to operat
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 3.1.2 POWER APPLICATION Apply DC power to the amplifier and use a DC voltmeter to confirm that
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 3.3.1 SAFETY CONSIDERATIONS Don’t let safety be an afterthought. Before beginning
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA • Passing a cord over a roll on its way to the transducer will cause some amount of friction.
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 3.5 PROPER PRACTICES FOR APPLYING CALIBRATION FORCES Seldom is a transducer orient
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA Examples of Force Loss due to Friction at Driven Roll In this example, only a fraction of the
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA important to use a non-conductive tool to alter switch positions. Be sure that jum
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 3.10 GAIN AND FINE ZERO CALIBRATION Use the following steps to make your final calibration ad
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 3.11 EMC CONNECTIONS AND INSTALLATION Compliance with the specified EMC directive,
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA Appendix A. MANUFACTURERS DECLARATION OF CONFORMITY Number: AO-90311 Manufacturer: Cleve
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA TABLE OF CONTENTS 1 PRODUCT OVERVIEW...
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA Appendix B. CABLE GLANDS Several manufacturers provide cable glands that can be
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA WARRANTY Cleveland Motion Controls warrants the goods against defects in design,
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 1 PRODUCT OVERVIEW 1.1 GENERAL DESCRIPTION The Ultra Series DIN Rail amplifier (Isolated) prov
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 1.1.1 CE EMC RESPONSIBILITY Cleveland Motion Controls DIN Rail Amplifier MWI-13261
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA 1.2 GENERAL SPECIFICATIONS Item Specification Comments Input Supply Power Supply Requirement
DIN RAIL AMPLIFIER, MWI-13261 ULTRA SERIES MAN-13261 ULTRA REV BA 1.4 ENVIRONMENTAL REQUIREMENTS Requirement Description Enclosure IP20 NEMA 1 Oper
MAN-13261 REV BA DIN RAIL AMPLIFIER, MWI-13261 ULTRA Figure 1 Block Diagram of Ultra Series DIN RAIL MWI -13261 PAGE 9 OF 30